IJET
  • Home
  • Topics
  • Call For Paper
  • Publication Charges
  • Archives
    • Current Issue
    • Past Issues
    • Upcoming Conference
    • Conference Issues
  • Indexing
  • IJET Policy
    • Plagiarism Policy
    • Malpractice Policy
    • Correction Policy
    • Publication Rights
    • Terms Conditions
    • Cancellation Refund
  • Contact Us

Submit your paper : editorIJETjournal@gmail.com


International Journal of Engineering and Techniques(IJET) Paper Title : Optimization of Harmonic Filtering Methods Produced by Single-Phase Non-Linear Charge (Case of Kinshasa Low-Voltage Power grid).

ISSN : 2395-1303
Year of Publication : 2021
10.29126/23951303/IJET-V7I1P16
Authors: Mathangila Kimeya Gogom Mathurin, Gomba Rodolphe, Lidinga Mobonda Flory, Okemba Rodrgue Armel Patrick, Haroun Abba Labana,Nsongo Timothée

         



MLA Style: -Mathangila Kimeya Gogom Mathurin, Gomba Rodolphe, Lidinga Mobonda Flory, Okemba Rodrgue Armel Patrick, Haroun Abba Labana,Nsongo Timothée , " Optimization of Harmonic Filtering Methods Produced by Single-Phase Non-Linear Charge (Case of Kinshasa Low-Voltage Power grid). " Volume 7 - Issue 1 January - February,2021 International Journal of Engineering and Techniques (IJET) ,ISSN:2395-1303 , www.ijetjournal.org

APA Style: -Mathangila Kimeya Gogom Mathurin, Gomba Rodolphe, Lidinga Mobonda Flory, Okemba Rodrgue Armel Patrick, Haroun Abba Labana,Nsongo Timothée , " Optimization of Harmonic Filtering Methods Produced by Single-Phase Non-Linear Charge (Case of Kinshasa Low-Voltage Power grid). " Volume 7 - Issue 1 January - February,2021 International Journal of Engineering and Techniques (IJET) ,ISSN:2395-1303 , www.ijetjournal.org

Abstract
- In this article, we present different mathematical methods for harmonic filtering in the electrical energy distribution network. The equations developed address the harmonic problem in the electrical energy distribution station. In this part, we consider a set of stabilizers. The artery has a non-zero impedance (Rth and Xth). Similarly, each stabilizer is connected to the main artery by a line with a non-zero impedance (Rb and Xb). This configuration has the particularity of being more realistic and giving more precise results, but its approach remains more complex. The purpose of this article is to evaluate the effectiveness of different methods of harmonic filtering. As far as passive filtering is concerned, the configuration of parallel resonant and damped filters is studied theoretically and by simulation. Many active filter configurations can be encountered, but all are based on a stabilizer and plasma screen (with power transistors and diodes), a continuous source of voltage or filtering and coupling current.

Reference
[1] Hirofumi Akagi, « Control strategy and site selection of a shunt active filter for damping of harmonic propagation in power distribution systems», IEEE Transactions on Power Delivery, Vol. 12, No 1, pp.354-363, January 1997. [2] Su Chen and Géza Joos « Analysis and comparison of passive and active harmonic suppression filters in distribution systems», Electrical and Computer Engineering, 2000 Canadian Conference,Vol. 2 , pp.615-619, 7-10 March 2000. [3] M.J. Bridgeman, Norman MacLeod, S.B. Tennakoon, and R.E. Morrison, « The resonance damping effect associated with linear shunt loads and single-phase converters», Harmonies and Quality of Power, 2000. Proceedings. Ninth International Conference, Vol. 2, pp.535-540, 1-4 October 2000. [4] Evan J. Currence, John E. Plizga, and Howard N. Nelson, « Harmonie resonance at medium-sized industrial plant», IEEE Transactions on Industry Applications, Vol. 31, No4, pp.682-690, July/August 1995. [5] Fang Z. Peng, Gui-Jia Su, and George Farquharson « A series LC filter for harmonie compensation of ac drives», Power Electronics Specialists Conference, PESC 99. 30th annual IEEE, VoLl , pp. 213-218, 1999. [6] H. Sasaki and T. Machida, « A new method to eliminate ac harmonic currents by magnetic compensation-consideration on basic design», IEEE Transactions on Power Appl. Syst.,Vol. 90, No 5, pp.2009-2019, 1971. [7] Fang-Zhang Peng, Hirofumi Akagi, and Akira Nabae, Fellow, IEEE, «A study of active power filters using quad-series voltage-source PWM converters for harmonic compensation», IEEE Transactions on Power Electronics, Vol. 5, No 1, pp. 9-15, January 1990.
Keywords
Optimization of methods, Harmonic filtering, Grid, Distribution

IJET Management

  • Archives
  • Aim & Scope
  • Current Issues
  • special issue
  • Conferences Gallery
  • Review process
  • Impact factor
  • Board members
  • Publication ethics
  • Copyright infringement
  • Join as a Reviewer
  • Faq
  • Journal Update

    Downloads

  • CopyrightForm
  • Paper Template
  • Registration Form
Copyright © 2015 IJET- International Journal of Engineering and Techniques Published By International Research Group , All rights reserved

Plagiarisma        PCX
This work is licensed under a Creative Commons Attribution 4.0 (International) Licence. (CC BY-NC 4.0)